Wait a second...
Nepřihlášený uživatel
You are here: UCT PragueFETÚTVP  → Research → Equipment → Chemical analyses of water
iduzel: 40711
idvazba: 43666
šablona: stranka
čas: 25.4.2024 16:39:42
verze: 5351
uzivatel:
remoteAPIs:
branch: trunk
Server: 147.33.89.153
Obnovit | RAW
iduzel: 40711
idvazba: 43666
---Nová url--- (newurl_...)
domena: 'tvp.vscht.cz'
jazyk: 'en'
url: '/research/40706/40711'
iduzel: 40711
path: 8548/4168/4169/4171/18930/40706/40711
CMS: Odkaz na newurlCMS
branch: trunk
Obnovit | RAW

Chemical analyses of water

 

Isotachophoresis ITP / CZE-IONOSEP 2005 with additional UV / VIS detector ECD 2000

Contact: Dr. Jana Bartáčková

b jana.bartackova@vscht.cz  e 220 44 4374

 

  • Determination of anions and cations in water

 

Gas chromatograph FISONS  GC 8130 with FID

Contact: Dr. Dana Pokorná

b dana.pokorna@vscht.cz  e 220 44 3151

 

  • Determination of lower fatty acids - acetic, propionic, isobutyric, butyric, isovaleric, valeric, caproic - in water
 

Gas chromatograph HP 5890 with FID and ECD - Hewlett-Packard, USA

Contact: Prof. Václav Janda

b vaclav.janda@vscht.cz  e 220 44 3145

 

  • Analysis of volatile organic compounds
 

Gas chromatograph-mass spectrometer Fisons GC 8000 / MD 800, GB

Contact: Prof. Václav Janda

b vaclav.janda@vscht.cz  e 220 44 3145

 

  • Identification and analysis of volatile organic compounds
 

Gas chromatograph GC SHIMADZU 2010 with FID detector 

Contact: Dr. Jana Bartáčková

b jana.bartackova@vscht.cz  e 220 44 4374

 

  • Determination of NEL and aliphatic uhlovodíků
 

Agilent Infinity 1290 / 1290II Chromatography System with DAD Detection and MS Agilent 6460 Type QqQ (ESI)

Contact: Dr. Štěpánka Smrčková

b stepanka.smrckova@vscht.cz  e 220 44 5215

 

  • Quantitative determination of organic substances
 

HP 1050 high performance liquid chromatograph with multiply wavelength and fluorescence detector, HP, USA

Contact: Prof. Václav Janda

b vaclav.janda@vscht.cz  e 220 44 3145

 

  • Analysis of organic matter
 

AAS-908 AA - GBC, Australia

Contact: Assoc. Prof. Nina Strnadová

b nina.strnadova@vscht.cz  e 220 44 3148

 

  • Atomic Absorption Spectroscopy (atomisation and flame atomization)
 

UV/VIS-916 Spektrophotometer - GBC, Australia

Contact: Assoc. Prof. Nina Strnadová

b nina.strnadova@vscht.cz  e 220 44 3148

 

  • Spectrophotometric analysis in the range of 200 - 900 nm, manual and automatic spectral time scan
 

Spectrophotometer UV-1700PhamaSpec SHIMADZU

Contact: Assoc. Prof. Jana Říhová Ambrožová

b jana.ambrozova@vscht.cz  e 220 44 5123

 

  • Working range of wavelengths 1100 nm to 190 nm, possibility of connection to PC and printer, cuvette extension (1 and 5 cm glass and quartz cuvettes)
 

Apparatus for separating nonionic surfactants

Contact: Assoc. Prof. Ing. Vladimír Sýkora

b vladimir.sykora@vscht.cz  e 220 44 3229

 

  • Determination of non-ionic surfactants according to ČSN ISO 7875-2 (separation of surfactants by sublatations prior to their own analysis)
 

Shimadzu TOC-V CPH with a measuring unit TNM-1

Contact: Assoc. Prof. Ing. Vladimír Sýkora

b vladimir.sykora@vscht.cz  e 220 44 3229

 

  • Carbon analyzer
  • Differential determination of dissolved organic and inorganic carbon (DOC, IC) according to ČSN ISO 8245
  • Determination of dissolved non-removable and degradable organic carbon (NPOC, POC)
  • Determination of dissolved total nitrogen (TN)
 

Shimadzu TOC-5000A

Contact: Assoc. Prof. Ing. Vladimír Sýkora

b vladimir.sykora@vscht.cz  e 220 44 3229

 

  • Carbon analyzer
  • Differential determination of dissolved organic and inorganic carbon (DOC, IC) according to ČSN ISO 8245
  • Determination of dissolved non-recoverable organic carbon (NPOC)
  • Determination of TOC and IC in solid samples according to ČSN EN 13 137
 

LTX 2000 - LABTECH s.r.o., Czech Rep.

Contact: Dr. Jan Bindzar

b jan.bindzar@vscht.cz  e 220 44 5125

 

  • Group determination of organic halogenated substances
  • Determination of adsorbable organically bound halogens (AOX) in both solid and liquid samples
  • Determination of extractable organically bound halogens (EOX) in solid samples
  • Determination of adsorbable organic bound iodine (AOI) in both solid and liquid samples
Updated: 3.10.2017 21:55, Author: Lucie Pokorná

UCT Prague
Technická 5
166 28 Prague 6 – Dejvice
IČO: 60461373 / VAT: CZ60461373

Czech Post certified digital mail code: sp4j9ch

Copyright: UCT Prague 2017
Information provided by the Department of International Relations and the Department of R&D. Technical support by the Computing Centre.
switch to mobile version